Sê o primeiro a adicionar este livro aos favoritos!
BEHAVIOUR OF CFA, DRIVEN AND BORED PILES IN RESIDUAL SOIL. INTERNATIONAL PREDICTION EVENT - EXPERIMENTAL SITE - ISC'2
Author(s): António Joaquim Pereira Viana da Fonseca
Jaime A. Santos
Editors: Faculdade Engenharia da Universidade do Porto
Instituto Superior Técnico
ISBN:9789727501043
Pages:670
Dimensions:240x175x38
Poids:1069
PRIX : 18.00€
SHIPPING TO PORTUGAL INCLUDED, by Regular/Editorial Mail, valid as long as this option is available to individuals.
Sending by Registered Mail will incur the current rate.
The current design practice of bored and driven piles in residual weathered formations is merely semi-empirical and based on bearing capacity analyses (in general, without deformation evaluation). Fully instrumented pile load test are very much informative for the elaboration of specific correlations between load-deformation behaviour and in situ tests results (and also fundamental soil mechanics parameters obtained from precise laboratory tests), for establishing well-based design criteria. A fundamental base to this is the execution of extensive site investigation campaigns, and laboratory characterization tests, over specific soil profiles, allowing a confident and flexible choice in input parameters for a pile prediction event (PPE), i.e., a Class A exercise. In the preparation of the 2nd International Conference on Site Characterization (ISC'2), held in Sept. 2004 at the Faculty of Engineering of the University of Porto (FEUP), Portugal, an experimental site, here situated, was launched for the purpose of organizing an international PPE, organized under the auspices of TC-16 and TC-18 of ISSMGE.. A very extensive site characterization including a large variety of in-situ tests and also pile load tests were prepared in this experimental site, under the sponsorship of 4 construction companies. Data compiled during the investigation and characterization of the site, identified a residual (saprolitic) granite soil of varying thickness, overlaying more or less weathered granite contacting high grade metamorphic rocks. These investigations comprised the application of several geophysical borehole and surface methods, namely: P and S-wave seismic refraction, reflection, cross-hole (CH), down-hole (DH), electrical resistivity imaging and ground probing radar (GPR), as well as mechanical tests, namely: SPT, CPT, PMT and DMT, among others. Undisturbed samples were retrieved and an extensive laboratory testing program was carried out, including oedometric consolidation tests, CK0D triaxial tests using local strain measuring devices and bender-extender elements, as well as resonant column tests.
Assunto: Geotecnia, Engenharia civil
Geotechnics, Civil engineering
Áreas do conhecimento: Ciências da engenharia e tecnologias::Engenharia civil
Engineering and technology::Civil engineering
Resumo
Na região noroeste de Portugal são dominantes solos residuais de granito, com características específicas e complexas, típicas de materiais "não-livros didáticos". A prática atual de projeto de pilhas entediadas e acionadas em formações resistidas residuais é meramente semi-empírica e baseada em análises de capacidade de rolamento (em geral, sem avaliação de liquidação). Os testes de carga de pilha totalmente instrumentados são muito informativos para a elaboração de correlações entre o comportamento de deformação da carga e os resultados dos ensaios in situ, para estabelecer critérios de projeto bem baseados. Realizou-se em 2004 um estudo minucioso na Universidade do Porto, com a execução de uma extensa investigação no local e testes de caracterização laboratorial, permitindo bons parâmetros de entrada para um evento de previsão de estacas. Este projeto, apoiado por 4 construtoras, fez uso de testes de carga de pilhas, com o objetivo de lançar um evento de previsão de classe A, ou seja, todas as previsões foram submetidas antes da condução de testes de carga de pilhas estáticas. Três tipos diferentes de pilhas foram executados: pilhas entediadas com invólucro temporário, broca de voo contínuo, CFA, pilhas com seção circular — diâmetro nominal phi600mm, e pilhas acionadas (seção quadrada, B=350mm). As pilhas foram carregadas axialmente para o fracasso. As previsões enviadas são retomadas, revelando superestimações surpreendentes nas capacidades de pilhas entediadas, enquanto para as pilhas acionadas houve uma subestimação dos ganhos devido a efeitos de instalação de pilhas (densificação, etc.). Neste artigo, uma abordagem simples para quantificar as cargas residuais do dedo do pé bloqueado será abordada.